TREVER®|JET
ION EXCHANGE RESINS
True monodisperse beads, ideally suited for use in high performance demineralization units.
TREVER®|JET Ions Exchange Resins: Products, values and
applications
TREVERJET ion exchange resins offer true monodisperse beads and are ideally suited for use in high performance demineralization units.
With a uniformity coefficient of 1.1, they allow high-performance operations with the lowest regenerant level possible. This reduces the CO2 footprint of the operating units efficiently.
Trademark | Type1 | Capacity | Uniformity | Remarks | |
---|---|---|---|---|---|
TREVERJET IXC1110/Na | SAC | ≥ 2.0 | ≤ 1.2 | High performance resin for softening, all type of systems | |
TREVERJET IXC1200/Na | SAC | ≥ 2.0 (Na+) | ≤ 1.2 | High performance softening and demineralization, | |
TREVERJET IXC1310/Na | SAC | ≥ 2.2 | ≤ 1.2 | Ultra high performance resin, | |
TREVERJET IXC1500/H | SAC | ≥ 2.0 (H+ form) | ≤ 1.2 | Condensate polishing. High crosslinking, exceptional stability. | |
TREVERJET IXC2050/H | SAC | ≥ 1.7 (H+ form) | ≤ 1.2 | Condensate polishing. Superior strength, uniform particle size for mixed beds | |
TREVERJET IXA1200/Cl | SBA | ≥ 1.35 | ≤ 1.2 | Demineralization. Strong base anion type 1, high performance, | |
TREVERJET IXA1500/OH | SBA | ≥ 1.0 (OH- form) | ≤ 1.2 | Condensate polishing. Superior strength, uniform particle size for mixed beds | |
TREVERJET IXA2000/Cl | SBA | ≥ 1.3 | ≤ 1.2 | Demineralization. Strong base anion type 2, high performance, | |
TREVERJET IXA3050/OH | SBA | ≥ 1.4 (Cl- form) | ≤ 1.2 | Condensate polishing. Superior strength uniform particle size for mixed beds | |
TREVERJET IXA6200/FB | WBA | ≥ 1.4 | ≤ 1.2 | Weak base anion for free mineral acid removal, | |
TREVERJET UPC1400/H | SAC | ≥ 2.0 | ≤ 1.2 | High operating capacity gel resin. Can be used in individual vessels | |
TREVERJET UPC4000/H | SAC | ≥ 1.9 | ≤ 1.1 | High purity, gel resin. Can be used in individual vessels | |
TREVERJET UPA1400/OH | SBA | ≥ 1.0 | ≤ 1.2 | High operating capacity gel resin. Can be used in individual vessels | |
TREVERJET UPA4000/OH | SBA | ≥ 1.0 | ≤ 1.1 | High purity, gel resin. Can be used in individual vessels | |
TREVERJET UPM1000 | SAC/SBA | ≥ 2.0/≥ 1.0 | ≤ 1.2 | Regenerable mixed bed for the production of ultrapure water | |
TREVERJET UPM4000 | SAC/SBA | ≥ 1.9/≥ 1.0 | ≤ 1.1 | Low rinse, high purity, low TOC and metals leakage. | |
TREVERJET UPM4100 | SAC/SBA | ≥1.9 /≥ 1.0 | ≤ 1.1 | Low rinse, very high purity, very low TOC and metals leakage. |